| Parameter |
7310 |
7315 |
|---|
| Wavelength Range |
320 to 1000nm |
198 to 1000nm |
|---|
| Light source |
Tungsten halogen lamp |
Xenon lamp |
|---|
| Resolution |
1nm |
1nm |
|---|
| Accuracy |
± 2nm |
± 2nm |
|---|
| Repeatibility |
± 0.5nm |
± 0.5nm |
|---|
| Spectral bandwidth |
5nm |
5nm |
|---|
| Photometric Transmittance |
0 to 199.9% |
0 to 199.9% |
|---|
| Photometric Absorbance |
-0.300 to 2.500 |
-0.300 to 2.500 |
|---|
| Photometric Accuracy |
± 1%T, ± 0.01Abs at 1.000 Absorbance |
± 1%T, ± 0.01Abs at 1.000 Absorbance |
|---|
| Photometric Resolution |
0.1%T, 0.001A |
0.1%T, 0.001A |
|---|
| Concentration Range |
-300 to 9999 |
-300 to 9999 |
|---|
| Concentration Resolution |
selec table 1/ 0.1/ 0.01/ 0.001 |
selec table 1/ 0.1/ 0.01/ 0.001 |
|---|
| Concentation Calibration |
Blank with a single standard or factor |
Blank with a single standard or factor |
|---|
| Concentration Units |
no units, %, ppm, EBC, SRM, mEq/l, mEq, M, mM, µM, nM, U, U/l, U/ml, g/l, mg/l, µg/l, ng/l, g/dl, mg/dl, µg/dl, mg/ml, µg/ml, ng/ml, µg/ul, ng/ul, mol/l, mmol/l |
no units, %, ppm, EBC, SRM, mEq/l, mEq, M, mM, µM, nM, U, U/l, U/ml, g/l, mg/l, µg/l, ng/l, g/dl, mg/dl, µg/dl, mg/ml, µg/ml, ng/ml, µg/ul, ng/ul, mol/l, mmol/l |
|---|
| Concentration Factor |
0.001 to 10000 |
0.001 to 10000 |
|---|
| Concentration Standard |
0.001 to 1000 |
0.001 to 1000 |
|---|
| Quantitation Range |
-300 to 9999 |
-300 to 9999 |
|---|
| Quantitation Resolution |
selec table 1/ 0.1/ 0.01/ 0.001 |
selec table 1/ 0.1/ 0.01/ 0.001 |
|---|
| Quantitation Calibration |
Blank with up to 6 standards |
Blank with up to 6 standards |
|---|
| Quantitation Curve fit algorithms |
Quadratic, quadratic through zero, linear, linear through zero, interpolate |
Quadratic, quadratic through zero, linear, linear through zero, interpolate |
|---|
| Kinetics Measurement time |
2 to 9999 seconds |
2 to 9999 seconds |
|---|
| Kinetics Calibration |
Blank with a single standard or factor |
Blank with a single standard or factor |
|---|
| Kinetics Display |
Graphical and concentration |
Graphical and concentration |
|---|
| Kinetics Analysis |
Concentration, rate of change, initial and final absorbance/%T |
Concentration, rate of change, initial and final absorbance/:%T |
|---|
| Kinetics Resolution |
selec table 1/ 0.1/ 0.01/ 0.001 |
selec table 1/ 0.1/ 0.01/ 0.001 |
|---|
| Spectrum Range |
320 to 1000nm |
198 to 1000nm |
|---|
| Spectrum Scan interval |
selec table 1, 2 or 5nm |
selec table 1, 2 or 5nm |
|---|
| Spectrum Analysis |
Absorbance or transmittance and peak and valleys |
Absorbance or transmittance and peak and valleys |
|---|
| GLP |
Current time and date, user ID, instrument lock and method lock |
Current time and date, user ID, instrument lock and method lock |
|---|
| Method storage |
240 |
240 |
|---|
| Results memory |
Limited by attached mass storage device |
Limited by attached mass storage device |
|---|
| Removable media |
USB (supplied) |
USB (supplied) |
|---|
| Outputs |
USB, Analogue, RS232, Integral printer |
USB, Analogue, RS232, Integral printer |
|---|
| Size (w x d x h) |
275 x 400 x 220mm |
275 x 400 x 220mm |
|---|
| Weight |
6kg |
6kg |
برچسب:
نویسنده: ساحل فرهادی
تاريخ: يکشنبه
21 خرداد
1396 ساعت: 18:38